FluoSolv®

FluoSolv® 5408 Aerosol

No reviews yet Write a Review
SKU:
FluoSolv-5408-Aerosol

Specifications: FluoSolv®5408 Composition (Typical) Conforming to the Boeing BAC 5408 specification Fluorinated Fluid Mixture: <35 wt% Trans-dichloroethylene: >40 wt% Water: <100 ppm Non-volatile residue: &…

$100.00
Adding to cart… The item has been added
Product Details

Specifications:

FluoSolv®5408 Composition (Typical)

  • Conforming to the Boeing BAC 5408 specification
  • Fluorinated Fluid Mixture: <35 wt%
  • Trans-dichloroethylene: >40 wt%
  • Water: <100 ppm
  • Non-volatile residue: <50 ppm (drums), <200 ppm (pails)
  • Appearance: Clear, Colorless


Download TDS:


Download MSDS:


Introduction

FluoSolv® 5408 Aerosol conforms to the Boeing BAC5408 specification for vapor degreasing. It has the same active ingredients of FluoSolv® 5408 in convenient aerosol form. It is a proprietary blend of nonflammable fluorinated solvents (HFO’s) and trans-1,2-dichloroethylene (t-DCE). FluoSolv® 5408 offers a NON-PFAS solution to precision degreasing of heavy duty grease and lubricants and also cold cleaning.

FluoSolv® 5408 Aerosol is a drop-in replacement for many 3M Novec Aerosols.

FluoSolv® 5408 Aerosol solvent leverages the chemical solvency of the fluid as well as its physical properties such as high density, low surface tension and low viscosity for optimal performance. Efficient cleaning requires the solvent to flow extremely close to the surface of the part to dissolve the contaminant or physically lift insoluble particulate contaminants away from the surface to be cleaned.

Fluosolv® 5408 Aerosol does not contain any PFAS per the "EPA Reporting and Recordkeeping Requirements for Perfluoroalkyl and Polyfluoroalkyl Substances", final rule dated September 28, 2023.


User Benefits

NuGenTec’s FluoSolv® 5408 Aerosol is ideally balanced to deliver performance, worker safety and desirable environmental properties while offering a solution that is better for the environment than traditional chemistries.

  • Non-PFAS Formulation
  • Conforms to Boeing BAC5408
  • Drop-in replacement for 3M Novec aerosol products
  • Low global warming potential (GWP)
  • Low toxicity; high allowable exposure limit (AEL);
  • Non-Flammable; Non-Hazardous
  • Chemically stable; will not go acid


Material Compatibility

FluoSolv® 5408 Aerosol conforms to everything on the Boeing BAC 5408 specification. Also it is compatible with all metals, ceramic and other non-conducting materials. Most elastomeric materials are compatible. It is recommended that all materials be tested prior to use.

Required Compatible Additional Testing
Metals Aluminum, Copper, S/S Titanium, Brass, Tungsten -
Elastomers Neoprene, Butyl Rubber, EPDM, Kynar (PVDF) Viton A & B, Kalrez**
Plastics Acrylic*, HDPE, PTFE, Nylon, PVC, Epoxy, Phenolic, ABS, Polycarbonate* -

**Viton & Kalrez are fluoroelastomers that tend to swell when exposed to fluorinated fluids; dimensional changes are reversible
*Acrylics & Polycarbonates in stressed conditions are more susceptible to solvent attack at elevated temperatures.


Physical Properties

Property NuGenTec FluoSolv® 5408 Aerosol Novec 72DE HCFC-141b TCE nPB
Density at 25°C (77°F) kg/liter [lb/gal] 1.27 [10.8] 1.28 [10.7] 1.23 [10.3] 1.46 [12.1] 1.35 [11.26]
Surface Tension at 25°C (77°F) dyne/cm 15.9 19 19.3 29.5 25.9
Viscosity at 25°C (77°F), cP 0.41 0.45 0.43 0.49 0.49
Vapor Pressure at 25°C (77°F) kPa 44.5 46.7 79.5 8.0 20.3
Heat of Vaporization @bp kJ/kg 282 218 147 236 58.8
Global Warming Potential(GWP/100year ITH) <15 43 725 Low n/a
Ozone Depleting Chemical 0 0 0 0 0.026
Volatile Organic Compounds (VOC) g/l 1207 g/L Yes No Yes 1,350 g/L
Flash Point °C [°F] None None None None <10
Worker Exposure Ceiling (ppm) None None Not Determined Not Determined 10
KB Value 103 52 56 129 125

 

Worker Safety

Data from acute toxicity studies of various ingredients has demonstrated that FluoSolv® 5408 Aerosol blend has low toxicity. It has a calculated AEL (Acceptable Exposure Limit) of 200 ppm based on its individual components. None of the ingredients in FluoSolv® 5408 Aerosol have any chronic or acute toxicity associated with them which makes it a worker friendly solvent.

Please refer to the SDS for information on detailed exposure limits and toxicity-related data.

NuGenTec’s FluoSolv® 5408 Aerosol is not classified as a flammable liquid per established definitions by NFPA or DOT. Flash point data and vapor flammability limits in air are shown in Table below .


Flammability

  Test Method FluoSolv® 5408
Flash Point (CC) ASTM D93 None
Flash Point (OC) ASTM D1310 None
Flammability in Air ASTM E681  

 

Features

To the best of our knowledge, this product is California Prop 65 compliant.